{"id":2853,"date":"2025-05-29T14:00:47","date_gmt":"2025-05-29T14:00:47","guid":{"rendered":"https:\/\/www.vanlieshoutelektra.nl\/geen-onderdeel-van-een-categorie\/five-mistakes-when-installing-temporary-distribution-boxes-and-how-to-avoid-them\/"},"modified":"2025-05-29T14:00:47","modified_gmt":"2025-05-29T14:00:47","slug":"five-mistakes-when-installing-temporary-distribution-boxes-and-how-to-avoid-them","status":"publish","type":"post","link":"https:\/\/www.vanlieshoutelektra.nl\/en\/news\/five-mistakes-when-installing-temporary-distribution-boxes-and-how-to-avoid-them\/","title":{"rendered":"Five mistakes when installing temporary distribution boxes and how to avoid them"},"content":{"rendered":"<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><strong>Temporary distribution boxes are indispensable at construction sites, events and temporary workplaces. Yet things often go wrong when installing or renting these installations, resulting in risks to safety, continuity and legal compliance. In this article you will read about the five most common mistakes when installing temporary distribution boxes and practical tools to avoid them. Whether you are an installer yourself or responsible for rental, these insights will help you get ahead of problems.   <\/strong><\/p>\n<h2 class=\"font-semibold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Why temporary distribution boxes require special attention<\/h2>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">Temporary distribution boxes ensure that electrical energy is distributed safely and efficiently in locations lacking a permanent connection. Due to their temporary nature and intensive use, correct installation and inspection is important. Errors can lead to failure, property damage or even dangerous situations for users and bystanders.  <\/p>\n<h2 class=\"font-semibold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Common mistakes with temporary distribution boxes<\/h2>\n<h3 class=\"font-semibold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Incorrect on-site placement<\/h3>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><strong>Example of an error<\/strong><\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">A distribution box is installed where it is not protected from weather conditions, mechanical damage or unauthorized access.<\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><strong>Impact<\/strong><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Short circuit or electrical failure due to moisture or dust ingress<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Unintentional failure due to collisions with machinery or passersby<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Unauthorized acts by unauthorized persons<\/li>\n<\/ul>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><strong>How do you prevent this?<\/strong><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Always place distribution boxes out of direct reach of vehicles and equipment.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Provide dry, stable ground and sufficient distance from water streams or mud.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Use concrete or plastic protection around the cabinet whenever possible.<\/li>\n<\/ul>\n<h3 class=\"font-semibold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Installation overload<\/h3>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Example of an error<\/strong><\/b><\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">The total power of connected machines is underestimated while additional users are added after installation.<\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Impact<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Automatic fuses blow, resulting in interruptions.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Overheating of pipes can cause melting or fire hazards.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Unnecessary wear and tear on components.<\/li>\n<\/ul>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">How do you prevent this?<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Make a power calculation in advance based on the expected maximum simultaneous usage.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Allow for possible expansions during the period of use.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Choose a distribution box with sufficient margin above the calculated power.<\/li>\n<\/ul>\n<h3 class=\"font-semibold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Improper or poor grounding<\/h3>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Example of an error<\/strong><\/b><\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">A temporary distribution box is placed on metal plates without adequate grounding, or control measurements are lacking at commissioning.<\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Impact<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Danger to life if electrical currents flow into the housing.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Failure to comply with NEN 1010\/ NEN-EN 61439 legislation.<\/li>\n<\/ul>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">How do you prevent this?<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Before commissioning, always check that the grounding pin is correctly positioned and connected.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Measure the earth diffusion resistance and record it in writing.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Repeat this check each time the cabinet is moved.<\/li>\n<\/ul>\n<h3 class=\"font-semibold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Incorrect or incomplete documentation<\/h3>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Example of an error<\/strong><\/b><\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">Documentation is missing or incomplete; for example, no overview of connected groups or no inspection report available on site.<\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Impact<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Difficult inspections and failure analysis.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Risk of fines when inspected by regulators.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Uncertainty among multiple stakeholders.<\/li>\n<\/ul>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">How do you prevent this?<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Always supply an up-to-date list of groups and loads when installing.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Keep the latest inspection report in a clearly marked folder near or in the distribution box.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Update documentation immediately after changes or maintenance.<\/li>\n<\/ul>\n<h3 class=\"font-semibold text-h4 leading-[30px] pt-[15px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Inadequate monitoring or periodic maintenance<\/h3>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Example of an error<\/strong><\/b><\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\">After installation, the distribution box is only looked at in case of malfunctions; periodic visual inspections and testing do not take place.<\/p>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">Impact<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Defects are noticed too late, resulting in failure or damage.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Defective operation of protective devices or ground fault circuit breakers.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Invisible wear and tear can escalate into dangerous situations.<\/li>\n<\/ul>\n<p class=\"text-body font-regular leading-[24px] pt-[9px] pb-[2px]\" dir=\"ltr\"><b><strong class=\"font-semibold\">How do you prevent this?<\/strong><\/b><\/p>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Immediately upon installation, establish a maintenance and inspection plan appropriate to the duration and intensity of use.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Perform regular visual checks and some functional tests (including operation of ground fault circuit breakers).<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Record all findings in a maintenance log.<\/li>\n<\/ul>\n<h2 class=\"font-semibold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Practical tips for installers and landlords<\/h2>\n<ul class=\"pt-[9px] pb-[2px] pl-[24px] list-inside list-disc pt-[5px]\">\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"1\">Always follow applicable standards such as NEN 1010 and NEN-EN 61439-4 for temporary electrical installations.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"2\">Use only certified and periodically inspected distribution boxes.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"3\">Provide in-house training to personnel, including recognizing risk factors at temporary installations.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"4\">Make clear agreements between landlord and user regarding responsibilities for inspection, use and maintenance.<\/li>\n<li class=\"text-body font-regular leading-[24px] my-[5px] [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ol]:!pb-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pt-0 [&amp;&lt;encoded_tag_closed \/&gt;ul]:!pb-0\" value=\"5\">Keep a checklist with each installation for installation, completion and periodic inspection.<\/li>\n<\/ul>\n<h2 class=\"font-semibold text-h3 leading-[40px] pt-[21px] pb-[2px] [&amp;_a]:underline-offset-[6px] [&amp;_.underline]:underline-offset-[6px]\" dir=\"ltr\">Security and safety with temporary distribution boxes<\/h2>\n<p data-start=\"223\" data-end=\"513\">Temporary distribution boxes are essential, but only when properly deployed and maintained. By being aware of the most common mistakes and actively preventing them, you minimize risk and maximize reliability and safety on the job site. <\/p>\n<p data-start=\"515\" data-end=\"855\">As an experienced <a href=\"https:\/\/www.vanlieshoutelektra.nl\/\">electrical installation company in Helmond<\/a>, we support the supply and installation of reliable temporary power supplies. Think of a <a href=\"https:\/\/www.vanlieshoutelektra.nl\/schakelkast-op-maat\/\">customized switch box<\/a> for specific applications or solutions for temporary heating of a large space, tailored to your situation. <\/p>\n<p data-start=\"857\" data-end=\"1039\" data-is-last-node=\"\" data-is-only-node=\"\">Invest in clear procedures and regular inspections; this will keep your installation qualitative, safe and compliant. Would you like to know more? Then feel free to <a href=\"https:\/\/www.vanlieshoutelektra.nl\/contact\/\">contact<\/a> us.  <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Temporary distribution boxes are indispensable at construction sites, events and temporary workplaces. Yet things often go wrong when installing or renting these installations, resulting in risks to safety, continuity and legal compliance. In this article you will read about the five most common mistakes when installing temporary distribution boxes and practical tools to avoid them. [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":2400,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[],"class_list":["post-2853","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/posts\/2853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/comments?post=2853"}],"version-history":[{"count":0,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/posts\/2853\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/media\/2400"}],"wp:attachment":[{"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/media?parent=2853"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/categories?post=2853"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vanlieshoutelektra.nl\/en\/wp-json\/wp\/v2\/tags?post=2853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}